With around 250 locations and 90 serve centers, we are represented in the most important economic regions of the world. The advantages are clear: short paths to our customers, fast response times and a shared language.
Externally supplied buffer gas for arrangement 2 unpressurized seals with a dry running containment seal. Buffer gas is maintained at a pressure less than seal chamber pressure.
A  Gas OUT
B  Gas IN
2  Flush (F)
3  Containment seal vent (CSV)
4  Containment seal drain (CSD)
5  Gas buffer inlet (GBI)
6  Seal chamber
Example seal: EagleBurgmann H75LG4-C dual pusher mechanical seal.
Key
1  Buffer gas panel
3  Containment seal vent (CSV)
4  Containment seal drain (CSD)
7  From buffer gas supply
FIL  Coalescing filter
FIT  Flow transmitter with local indicator
PCV  Pressure control valve
PIT  Pressure transmitter with local indicator
2CW-CS, 2NC-CS